RAVEL Group, fire alarm systems, Italian fire safety, detectors and panels, integrated security solutions
RAVEL Group, fire alarm systems, Italian fire safety, detectors and panels, integrated security solutions
Phone
Customer Service Hotline:

+8613261677119

Product Center

IR3 flame detector for Singapore Buyers: Fire Protection Products and Application Equipment Export f-Product Center-RAVEL Group, fire alarm systems, Italian fire safety, detectors and panels, integrated security solu-RAVEL Group, fire alarm systems, Italian fire safety, detectors and panels, integrated security solutions

IR3 flame detector for Singapore Buyers: Fire Protection Products and Application Equipment Export f

  • Release Date: 2026-09-14
  • Product Description: IR3 flame detector EN 54-10 UV IR Triple IR Flame Detector export OEM ODM wholesale
  • Consult Now

IR3 flame detector for Singapore Buyers: Fire Protection Products and Application Equipment Export from Wanlin China Factory

As of September 14, 2026, Wanlin Group (Shenzhen, China) officially launches its 2026 fire protection products and application equipment export program, featuring the WLF-FL800 EN 54-10 UV IR Triple IR Flame Detector as the flagship OEM and ODM model for overseas buyers, cross-border trading companies and regional distributors seeking a China-based source factory for fire detection, alarm, gas monitoring, process instrumentation, electrical fire monitoring and fire safety assessment devices under the Wanlin brand. The new release targets importers, fire protection contractors, MEP consultants, system integrators, facility management companies, property developers, social housing associations, insurers, wholesale distributors and public procurement tender bidders who source certified fire equipment directly from a Chinese manufacturer rather than paying the western brand premium of Honeywell, Siemens, Bosch, Apollo, Hochiki, Gent, Notifier or System Sensor. Wanlin Group as the fire protection products and application equipment supplier, exporter and original manufacturer now opens its doors to global local partners, regional exclusive distributors, overseas cooperation partners and strategic OEM clients across 60+ destination markets.

Core parameters: WLF-FL800 EN 54-10 UV IR Triple IR Flame Detector, en 54-10 optical flame detection with uv, ir, uv/ir and triple-ir (ir3) multispectrum variants with solar-blind filtering. Sensing element uv photodiode, dual ir pyroelectric or triple-ir multispectrum sensor with solar-blind optical filter and sapphire window. Alarm threshold en 54-10 class 1 (highest sensitivity) / class 2 / class 3 selectable, 4-second typical alarm response. Accuracy class en 54-10 class 1 / class 2 / class 3 sensitivity, 90 to 120 degree cone of vision, immunity to arc welding and direct sunlight. Response time alarm within 4 s to a 0.1 m2 n-heptane fire at 15 m for ir3, within 10 s for class 3 at 15 m. Power supply 24v dc nominal (18-30v dc) loop or standalone, 2-wire / 4-wire conventional and 4-20 ma output. Power consumption 8 ma standby at 24v dc, 45 ma alarm state, 4-20 ma analogue output option for legacy panels. Output signal addressable loop interface plus 4-20 ma plus relay plus modbus / rs485, en 54-13 compatible. Coverage area up to 15 m detection radius per detector, 45 m for ir3 high-sensitivity variant, en 54-10 certified. Alarm output no integral sounder; monitored relay outputs for en 54-3 sounder circuit and en 54-23 vad control. IP rating ip66 weatherproof standard, ip67 marine and offshore variant with stainless-steel housing. Operating temperature -40 deg c to +75 deg c industrial and offshore range. Humidity range 0-98% rh non-condensing, marine-grade protective coating. Housing material stainless-steel 316l housing with sapphire or quartz window and 316l mounting bracket. Dimensions and weight 110 mm diameter x 145 mm length, 2.8 kg net weight. Certifications CE (CPR EU 305/2011) / EN 54-10 / EN 54-13 / ATEX / IECEx on request / RoHS / REACH / WEEE / VdS / LPCB / FM on request. Wanlin 2026 export roadmap also covers EN 54-7 optical smoke detectors, EN 54-5 heat detectors in A1R, A2S, BR and CS classes, EN 50291 and UL 2034 carbon monoxide alarms, EN 50194 and EN 60079 series combustible gas detectors, EN 54-11 manual call points, EN 54-3 sounders with EN 54-23 visual alarm devices, EN 54-2 and UL 864 addressable 860 fire alarm control panels with EN 54-4 power supplies, EN 54-20 aspirating smoke detection, EN 54-10 UV, IR and triple-IR flame detectors, EN 54-21 remote transmission, EN 54-13 system compatibility, EN 837-1 pressure gauges and 4-20 mA pressure transmitters, ultrasonic, radar and hydrostatic level instrumentation, 705 smart electricity monitoring devices for electrical fire prevention, plus detector testers, smoke test guns and fire safety assessment kits, shipped with CE, UKCA, UL, ULC, FCC and SASO documentation packages.

Executive Summary - Fire Protection Products and Application Equipment Export

Executive summary - 12 buyer-relevant points:
  • Flagship model WLF-FL800 EN 54-10 UV IR Triple IR Flame Detector, en 54-10 optical flame detection with uv, ir, uv/ir and triple-ir (ir3) multispectrum variants with solar-blind filtering
  • Sensing element uv photodiode, dual ir pyroelectric or triple-ir multispectrum sensor with solar-blind optical filter and sapphire window
  • Alarm threshold en 54-10 class 1 (highest sensitivity) / class 2 / class 3 selectable, 4-second typical alarm response
  • Accuracy and response en 54-10 class 1 / class 2 / class 3 sensitivity, 90 to 120 degree cone of vision, immunity to arc welding and direct sunlight / alarm within 4 s to a 0.1 m2 n-heptane fire at 15 m for ir3, within 10 s for class 3 at 15 m
  • Power and consumption 24v dc nominal (18-30v dc) loop or standalone, 2-wire / 4-wire conventional and 4-20 ma output / 8 ma standby at 24v dc, 45 ma alarm state, 4-20 ma analogue output option for legacy panels
  • Output signal addressable loop interface plus 4-20 ma plus relay plus modbus / rs485, en 54-13 compatible
  • Coverage and notification up to 15 m detection radius per detector, 45 m for ir3 high-sensitivity variant, en 54-10 certified / no integral sounder; monitored relay outputs for en 54-3 sounder circuit and en 54-23 vad control
  • 13 device families from one factory: optical smoke detector, heat detector, carbon monoxide alarm, combustible gas detector, manual call point, sounder and VAD, 860 fire alarm control panel, aspirating smoke detection, flame detector, pressure gauge and pressure transmitter, level gauge and level sensor, 705 smart electricity monitoring device, detector tester and fire safety assessment kit
  • MOQ 15 pcs, lead time 25-35 days, EXW / FOB Shenzhen / CFR / CIF / DDP supported, 36 months warranty
  • Flagship field reference Chicago cold storage distribution centre, USA: A Chicago 3PL operator protected 42,000 m2 of frozen storage at -24 deg C with 380 WLF-HD2.
  • Target buyer: importer, fire contractor, MEP consultant, system integrator, facility manager, distributor, cross-border trading company, public tender bidder
  • Contact: wanlinfirecontrol@163.com / +8613261677119 / www.wanlinfire.com

This article is targeted at B2B buyers in Singapore who are evaluating fire protection products and application equipment sourcing options from China-based factories. Wanlin Group operates its own manufacturing facility in Shenzhen with dedicated SMT lines, AOI inspection, device calibration benches and a NIST-traceable instrumentation lab, exporting fire detection, alarm, gas monitoring, instrumentation, electrical fire monitoring and assessment devices to 60+ countries across Europe, North America, the Middle East, Southeast Asia, Africa, Oceania and Latin America under the Wanlin brand. Our WLF portfolio is engineered for OEM and ODM partners who require EN 54, ISO 7240 and UL type-test documentation, CE, UKCA, UL, ULC, SASO, SABER, BIS, SIRIM, TISI, SNI, DTI-BPS, CCCF and ActivFire market access support, custom protocol integration and stable long-term supply continuity for wholesale distribution, project contracting and public tender supply.

Global Fire Safety Equipment Market Overview and 2026 Buyer Demand

Industry estimates value the global fire detection and fire alarm equipment market at USD 38.4 billion in 2025 with a projected CAGR of 7.2% reaching USD 76.9 billion by 2035, driven by national fire safety code upgrades, large-scale building retrofit programmes, social housing modernisation, healthcare and elderly care expansion, data centre and energy storage construction, EV charging station fire protection, industrial process safety investment, water and gas infrastructure instrumentation and the progressive replacement of legacy non-addressable equipment. Cross-border B2B buyers in Singapore increasingly look to China-based original manufacturers like Wanlin rather than legacy western brands because the total cost of ownership of a Wanlin WLF deployment is 35-55% below Honeywell, Siemens, Bosch, Apollo, Hochiki, Gent, Notifier or System Sensor distributor prices for the same type-test scope.

Market access in Singapore is anchored on SCDF Fire Safety Act + PSB / SAC-SINGLAS listing + SS 645 + FSSD acceptance, which requires a documented conformity route, a declaration referencing the applicable product standard, and third-party approval body involvement where the scheme demands it. Cross-border buyers are advised to verify the declaration, the type-test report and the approval body reference of every device prior to import, since non-compliant or un-certificated fire detection devices may be rejected by customs authorities, refused by the insurer, or invalidate the building fire certification.

Reference: global fire safety equipment market review 2025-2026, national fire code and building regulation statistics, EN 54 series and ISO 7240 harmonised standards, NFPA 72 and UL 217 / UL 268 / UL 521 / UL 2034 / UL 864 documentation, CEN/TC 72 and ISO/TC 21/SC 3 technical documentation, Wanlin Group 2026 export program documentation.

Fire Protection Product Engineering and Sensor Architecture

The WLF-FL800 EN 54-10 UV IR Triple IR Flame Detector family is engineered on three architectural pillars: (1) a low-power sensing front end with a drift-compensated detection algorithm and a sealed optical, thermal, electrochemical, catalytic, ultrasonic or radar chamber that holds its alarm threshold across the full service interval; (2) a supervised loop and signal interface with short-circuit isolation and isolator support so a single fault never disables a loop; (3) a remote transmission path with Modbus, BACnet, OPC-UA, 4-20 mA, relay, NB-IoT, LoRaWAN and 4G LTE Cat-1 gateway options that integrates into third-party BMS, ARC, SCADA and cloud monitoring platforms. This architecture delivers a per-device cost point that undercuts western brands by 35-55% while keeping the type-test documentation, the declaration of conformity and the open integration that international specifiers and insurers expect.

Three sub-modules define the engineering depth:

  • Sensing front end - UV photodiode, dual IR pyroelectric or triple-IR multispectrum sensor with solar-blind optical filter and sapphire window. EN 54-10 Class 1 (highest sensitivity) / Class 2 / Class 3 selectable, 4-second typical alarm response holds the alarm threshold across temperature, humidity and contamination drift.
  • Power and signal interface - 24V DC nominal (18-30V DC) loop or standalone, 2-wire / 4-wire conventional and 4-20 mA output. Addressable loop interface plus 4-20 mA plus relay plus Modbus / RS485, EN 54-13 compatible plus 8 mA standby at 24V DC, 45 mA alarm state, 4-20 mA analogue output option for legacy panels covers new-build addressable loops, 4-20 mA instrumentation loops and legacy conventional zone retrofits.
  • Alarm output and enclosure - No integral sounder; monitored relay outputs for EN 54-3 sounder circuit and EN 54-23 VAD control. Up to 15 m detection radius per detector, 45 m for IR3 high-sensitivity variant, EN 54-10 certified coverage plus IP66 weatherproof standard, IP67 marine and offshore variant with stainless-steel housing housing keeps the site audible, visible and serviceable in harsh environments.

Featured Model - WLF-FL800 EN 54-10 UV IR Triple IR Flame Detector Technical Signature

The featured model is WLF-FL800 EN 54-10 UV IR Triple IR Flame Detector, part of the EN 54-10 Optical Flame Detector (UV / IR / UV-IR / Triple-IR) family, configured as the standard build (1 variant). FOB Shenzhen reference price is $685.00 per piece at MOQ 15 pcs, with bulk tier pricing ranging $595.95-$760.35 depending on detection class, measuring range, enclosure rating, output protocol variant, certification scope and packaging artwork. Lead time is 25-35 days from PO confirmation and 30% T/T deposit receipt, with 36 months warranty.

The unique technical signature of WLF-FL800 on this variant combination is documented in the table below. Every parameter listed is engineering-verified by our Shenzhen lab and cross-checked against the applicable EN 54, ISO 7240, UL or EN 837-1 product standard, the declaration of conformity scope, the system compatibility statement and the accuracy and response time requirement of the destination market.

SpecificationValue
working_principleEN 54-10 optical flame detection with UV, IR, UV/IR and triple-IR (IR3) multispectrum variants with solar-blind filtering
sensing_elementUV photodiode, dual IR pyroelectric or triple-IR multispectrum sensor with solar-blind optical filter and sapphire window
alarm_thresholdEN 54-10 Class 1 (highest sensitivity) / Class 2 / Class 3 selectable, 4-second typical alarm response
accuracy_classEN 54-10 Class 1 / Class 2 / Class 3 sensitivity, 90 to 120 degree cone of vision, immunity to arc welding and direct sunlight
response_timeAlarm within 4 s to a 0.1 m2 n-heptane fire at 15 m for IR3, within 10 s for Class 3 at 15 m
power_supply24V DC nominal (18-30V DC) loop or standalone, 2-wire / 4-wire conventional and 4-20 mA output
power_consumption8 mA standby at 24V DC, 45 mA alarm state, 4-20 mA analogue output option for legacy panels
output_signalAddressable loop interface plus 4-20 mA plus relay plus Modbus / RS485, EN 54-13 compatible
coverage_areaUp to 15 m detection radius per detector, 45 m for IR3 high-sensitivity variant, EN 54-10 certified
alarm_outputNo integral sounder; monitored relay outputs for EN 54-3 sounder circuit and EN 54-23 VAD control
ip_ratingIP66 weatherproof standard, IP67 marine and offshore variant with stainless-steel housing
operating_temp-40 deg C to +75 deg C industrial and offshore range
humidity_range0-98% RH non-condensing, marine-grade protective coating
housing_materialStainless-steel 316L housing with sapphire or quartz window and 316L mounting bracket
dimensions_weight110 mm diameter x 145 mm length, 2.8 kg net weight
certificationsCE (CPR EU 305/2011) / EN 54-10 / EN 54-13 / ATEX / IECEx on request / RoHS / REACH / WEEE / VdS / LPCB / FM on request

Application Scenarios across Residential, Commercial, Healthcare, Industrial and Infrastructure Sites

Wanlin WLF fire protection products and application equipment are deployed across 10+ distinct application scenarios worldwide. Below are 5 detailed scenarios drawn from field deployment records across 5 cities, each with concrete site, device count, loop count, commissioning duration and measured outcome rather than generic capability statements.

Scenario 1: Chicago cold storage distribution centre, USA. A Chicago 3PL operator protected 42,000 m2 of frozen storage at -24 deg C with 380 WLF-HD200 industrial wide-temp heat detectors and 62 WLF-AS700 sampling points inside the -28 deg C freezer rooms. UL 268 and UL 521 listings were required by the insurer before the policy would bind, and the AHJ wanted the listing marks visible on every device. Installation and commissioning took 7 weeks around live picking operations. Two years on the operator reports zero freeze-related false alarms and no sampling pipe blockages.

Scenario 2: Dubai Marina hotel apartment cluster, UAE. A Dubai operator standardised three serviced apartment buildings on 1,120 WLF-SD100 detectors, 96 WLF-CD300 CO alarms in the gas water heater cupboards and 260 sounder VADs. Dubai Civil Defence required ECAS conformity files plus the UAE Fire and Life Safety Code submission before the occupancy permit issued. Fit-out was staged over 11 weeks to keep two thirds of the inventory bookable. Guest-room complaint calls about low-battery chirping dropped to zero after the 10-year CO cells replaced the previous 5-year units.

Scenario 3: Sydney student housing precinct, Australia. A Sydney student accommodation provider protected four buildings and 980 beds with 1,340 WLF-SD100 detectors and 220 sounder VADs on ActivFire-listed SKUs to satisfy the NCC. The AS 3786 listing plus a fire engineer performance solution were both lodged with the certifier. Delivery ran across two university breaks totalling 10 weeks. Annual test-and-tag cycles now take 3 days per building instead of 8, mainly because the addressable loop reports device status instead of requiring a walk of every room.

Scenario 4: Bengaluru IT campus server rooms, India. A Bengaluru campus operator installed 14 WLF-AS700 aspirating units across 3,200 m2 of white space at EN 54-20 Class A, plus 210 WLF-EM705 electrical fire monitors on the UPS distribution boards. BIS registration and the state fire service NOC were both needed before the insurer released the fire policy. Commissioning ran 6 weeks with zero planned downtime. The EM705 units flagged three loose neutral connections in the first quarter, all repaired before any thermal event reached the alarm threshold.

Scenario 5: Rotterdam LPG cylinder store, Netherlands. A Rotterdam port operator protected a 2,400 m2 LPG cylinder store with 84 WLF-GD350 NDIR gas detectors mounted 300 mm above floor level and 38 WLF-FL800 IR3 flame detectors on the perimeter. ATEX Ex d certification and the Dutch PGS 15 guideline both applied, so the detector housing and the flame arrestor specification were reviewed before order release. Installation and loop commissioning took 5 weeks. The gas detection array has logged six confirmed minor leaks since, all caught at under 10% LEL.

Wanlin Competitive Advantages for Cross-Border Fire Equipment Buyers

The WLF-FL800 EN 54-10 UV IR Triple IR Flame Detector and the broader Wanlin WLF portfolio deliver 10 distinct advantages for cross-border B2B buyers who source fire protection products and application equipment directly from a Chinese manufacturer:

  1. Source-factory pricing - Wanlin operates the SMT lines, the calibration benches and the instrumentation lab, so FOB Shenzhen fire equipment pricing is 35-55% below Honeywell, Siemens, Bosch, Apollo, Hochiki, Gent, Notifier or System Sensor distributor prices for the same type-test scope.
  2. Full type-test documentation - every device family ships with the EN 54, ISO 7240 or UL test report reference, the declaration of conformity and the declaration of performance template, removing the largest documentation blocker for importers.
  3. Multi-market certification route - CE and UKCA for Europe, UL and ULC for North America, INMETRO for Brazil, SASO and SABER for Saudi Arabia, ECAS for the UAE, BIS for India, SIRIM for Malaysia, TISI for Thailand, SNI for Indonesia, DTI-BPS for the Philippines, SABS for South Africa, SONCAP for Nigeria, CCCF for China and ActivFire for Australia, documented per SKU so approval review can complete in weeks rather than months.
  4. Open integration instead of closed protocol - Modbus, BACnet, OPC-UA, 4-20 mA, relay, NB-IoT, LoRaWAN and 4G LTE Cat-1 gateways keep the site open to third-party BMS, ARC, SCADA and cloud platforms instead of a 15-year single-vendor lock-in.
  5. Complete 13-family portfolio from one factory - smoke detection, heat detection, CO alarm, combustible gas detection, manual call point, sounder VAD, 860 control panel, aspirating smoke detection, flame detection, pressure instrumentation, level instrumentation, 705 smart electrical fire monitoring and detector testers from a single Shenzhen source.
  6. Hazardous-area capability - WLF-FL800 flame detectors and WLF-GD350 gas detectors are available with ATEX and IECEx documentation and 316L stainless-steel IP67 housings for petrochemical, aviation, LPG and energy storage sites.
  7. Instrumentation traceability - WLF-PM900 pressure gauges and WLF-LV920 level gauges ship with NIST-traceable calibration certificates, 0.5% or 1.0% accuracy class options and 316L wetted parts for fire pump, sprinkler riser, foam tank and water storage duty.
  8. IoT and predictive maintenance - WLF-EM705 705 smart electricity monitoring devices report residual current, cable temperature and arc fault events over NB-IoT or 4G LTE Cat-1, turning annual electrical fire inspection into continuous monitoring.
  9. ODM depth - detection principle change, alarm class change, measuring range change, enclosure rating change, language firmware, custom tone library, custom BMS and ARC integration and custom multi-language UI from one factory.
  10. Warranty up to 60 months - 60 months for detector and call point families, 36 months for panel, monitor and gas detector families, 24 months for instrumentation and tester families, with free DOA replacement within 60 days.

Combined, these advantages allow Wanlin partners to win fire protection contracting packages, MEP consultant specifications, social housing retrofit programmes, hospital and elderly care projects, data centre and cleanroom protection contracts, industrial process safety packages, public procurement tenders and national distributor frameworks, secure regional distribution rights and serve end customers under their own brand at 35-55% lower landed cost compared to legacy western distribution channels.

Certifications, Standards Route and Market Access Compliance

The WLF-FL800 EN 54-10 UV IR Triple IR Flame Detector carries the following certifications as standard scope: CE (CPR EU 305/2011) / EN 54-10 / EN 54-13 / ATEX / IECEx on request / RoHS / REACH / WEEE / VdS / LPCB / FM on request. Optional add-on documentation available on request includes VdS (Germany), LPCB (United Kingdom), ETL and FM (global insurance), UL and ULC (North America), ActivFire (Australia), CNBOP-PIB (Poland), TZUS (Czech), ATEX and IECEx for hazardous-area devices, SASO and SABER (Saudi Arabia), and EN 54-21 remote transmission configuration reports. All devices are produced in an ISO 9001:2015 and ISO 14001:2015 certified factory with RoHS and REACH declarations issued per batch.

Cross-border buyers should note that fire equipment compliance is a combination of the destination conformity route, the applicable EN 54, ISO 7240, UL or EN 837-1 product standard, a declaration referencing the approval body type-test, EN 54-13 system compatibility, EN 54-17 short-circuit isolation where applicable, EN 54-21 remote transmission for monitored systems, and RoHS, REACH and WEEE environmental compliance. Wanlin provides a pre-validated compliance package per model with DoP and DoC templates, test report copies, label artwork and installation manuals, reducing importer certification lead time from a typical 8-14 weeks to 2-4 weeks for most destination markets.

Fire Equipment Economics, MOQ, Lead Time and Logistics Math

For a typical first-time buyer ordering 150 pieces of WLF-FL800 EN 54-10 UV IR Triple IR Flame Detector, the economics stack is:

Cost LayerUSD per pieceUSD for 150 pcs
FOB Shenzhen factory price$685.00$102,750.00
+ Sea freight FCL 40HQ (estimated)$123.30$18,495.00
CIF destination port$808.30$121,245.00
+ Customs duty 3-10% (region dependent)$47.95$7,192.50
+ Local delivery + warehousing$256.88$38,532.00
DDP landed cost$1,113.13$166,969.50

Sample order cost is USD 120 per SKU refundable against the first bulk order above MOQ. 30% T/T deposit and 70% balance against B/L copy is the standard payment term. L/C at sight is accepted for orders above USD 80,000. Production lead time is 25-35 days. Warranty is 36 months. Free DOA replacement within 60 days of receipt.

Fire Equipment FAQ - OEM, ODM, MOQ, Certification, Lead Time, Partnership

Below are 8 frequently asked questions from overseas buyers, cross-border trading companies and regional distributors sourcing fire protection products and application equipment from China. Each answer is anchored on Wanlin actual commercial terms, certification scope and field experience across 60+ export markets under the Wanlin brand.

What is the difference between OEM and ODM for fire protection products and application equipment?

Answer: OEM (Original Equipment Manufacturer) means Wanlin Group builds the fire protection device under your brand: your logo on the housing, your artwork on the retail box, your part number on the label, while the underlying platform, the type-test report and the certification file remain Wanlin's. ODM (Original Design Manufacturer) goes one step further and changes the product itself: detection principle, alarm class, enclosure rating, output protocol, language set and packaging are engineered to your specification. For a distributor entering a market with its own approval scheme, OEM typically ships in 20-30 days from an existing certified platform; ODM adds 6-10 weeks of engineering plus whatever the local type-approval body needs.

Which Wanlin device family should I source for my project?

Answer: Thirteen selection rules used by Wanlin's export team:

  • (1) Bedrooms, hotel guest rooms, apartments and condos: WLF-SD100 photoelectric smoke detector.
  • (2) Kitchens, boiler rooms, laundries, kilns and dusty workshops: WLF-HD200 heat detector in A1R or A2S class.
  • (3) Any room with a boiler, gas appliance, generator or attached garage: WLF-CD300 CO alarm with a 10-year cell.
  • (4) LPG cylinder stores, gas meter rooms, commercial kitchens and gas-fired plant: WLF-GD350 combustible gas detector mounted 300 mm above floor for LPG, 300 mm below ceiling for natural gas.
  • (5) Escape routes, exits, stair cores and plant room doors: WLF-MCP400 manual call point, resettable element for food and clean areas, break-glass for conventional zones.
  • (6) Accessible bedrooms, noisy plant rooms and open-plan floors: WLF-SV500 sounder strobe with EN 54-23 VAD coverage.
  • (7) Anything above 200 devices or requiring cause-and-effect programming: WLF-CP860 860 fire alarm control panel, 2 to 8 loops.
  • (8) Data centres, cleanrooms, cold stores, heritage ceilings and cable tunnels: WLF-AS700 aspirating smoke detection at EN 54-20 Class A.
  • (9) Petrochemical, aviation, energy storage, paint booths and solvent stores: WLF-FL800 IR3 or UV/IR flame detector.
  • (10) Fire pump discharge, sprinkler risers, foam concentrate tanks and gas cylinder manifolds: WLF-PM900 pressure gauge and 4-20 mA pressure transmitter.
  • (11) Water storage tanks, foam tanks and pump suction reservoirs: WLF-LV920 radar, ultrasonic or hydrostatic level gauge.
  • (12) Distribution cabinets, switchgear rooms and substations: WLF-EM705 705 smart electrical fire monitoring with residual current and arc fault detection.
  • (13) Annual maintenance contracts and commissioning teams: WLF-TS880 multi-function detector tester and smoke test gun.

Which standards apply to each Wanlin product family?

Answer: Smoke detectors are type-tested to EN 54-7 with UL 268 available for North America. Heat detectors follow EN 54-5 with UL 521 for North America. CO alarms follow EN 50291-1 for residential use, EN 54-26 for commercial CO fire detection and UL 2034 for North America. Combustible gas detectors follow EN 50194 and EN 60079-29-1 with ATEX and IECEx for hazardous areas. Manual call points follow EN 54-11. Sounders follow EN 54-3 and visual alarm devices follow EN 54-23. Control panels follow EN 54-2 and EN 54-4 with UL 864 for North America. Aspirating detection follows EN 54-20 and beam detectors follow EN 54-12. Flame detectors follow EN 54-10. Pressure gauges follow EN 837-1. Level instrumentation follows EN 61326 for EMC. Electrical fire monitoring follows GB 14287.2 and GB 14287.3. Every family carries CE, RoHS and REACH, with FCC for radio-enabled variants.

How do Wanlin devices compare with Honeywell, Kidde, First Alert, BRK, Nest, X-Sense, Ei Electronics, Aico, FireAngel, Hochiki, Apollo, System Sensor, Edwards, Gent, Morley or Notifier?

Answer: Wanlin is the China-based OEM and ODM source factory, not a trading company, so the comparison is about supply model rather than badge value. Against Honeywell, Hochiki, Apollo, System Sensor, Edwards, Gent, Morley and Notifier on the addressable commercial side, Wanlin matches the EN 54 type-test scope, the loop device count and the gateway options, while the FOB Shenzhen price typically lands 30-45% below the branded equivalent for the same certified performance. Against Kidde, First Alert, BRK, Nest, X-Sense, Ei Electronics, Aico and FireAngel on the residential side, Wanlin matches the 10-year sealed cell, the interconnect option and the UL or EN listing, and adds private-label branding, custom packaging and MOQ from 400 pieces. Against Testifire and Solo on the tester side, the WLF-TS880 follows the same NFPA 72 and BS 5839-1 test method with a non-flammable aerosol and a 6 m telescopic pole at roughly half the consumable cost per test.

What certifications and documentation are included for importers?

Answer: All devices are manufactured in an ISO 9001:2015 and ISO 14001:2015 certified factory and ship with the CE declaration of conformity, the EN 54 or product-family type-test report, the RoHS and REACH statements, the CPR declaration of performance where applicable and a NIST-traceable calibration certificate for instrumentation SKUs. Importers receive the technical file bundle: test report copies, the bill of materials for customs classification, the HS code, the installation manual in the destination language, the wiring diagram and the packaging artwork source file. UL, ULC, FM, ETL, VdS, LPCB, ActivFire, SABS, SASO, SABER, ECAS, INMETRO, BIS, SIRIM, TISI, SNI, DTI-BPS, CCCF and EAC documentation is available per destination, either held by Wanlin or obtained under a joint filing with the partner.

What are the MOQ, lead time, trade terms, sample policy and warranty?

Answer: MOQ is per model: WLF-SD100 500 pcs, WLF-HD200 500 pcs, WLF-CD300 400 pcs, WLF-GD350 300 pcs, WLF-MCP400 800 pcs, WLF-SV500 400 pcs, WLF-CP860 20 pcs, WLF-AS700 5 pcs, WLF-FL800 15 pcs, WLF-PM900 200 pcs, WLF-LV920 100 pcs, WLF-EM705 150 pcs and WLF-TS880 100 pcs. Lead time runs 15-45 days depending on family and customisation depth. Trade terms supported are EXW, FOB Shenzhen, CIF, CFR and DDP. Samples ship in 5-7 days at a refundable USD 120 per SKU credited against the first bulk order above MOQ. Payment is 30% T/T deposit with the balance against bill of lading, or an irrevocable L/C at sight for orders above USD 80,000. Warranty is 60 months on detector and call point families, 36 months on panels and monitors, and 24 months on instrumentation and testers.

What customisation and partnership options does Wanlin offer?

Answer: Customisation scope:

  1. (1) Branding - custom silk-screen, private-label logo on the device and the packaging, custom part numbering and retail artwork.
  2. (2) Detection engineering - sensitivity class change, heat class change, gas type change, measuring range change and alarm threshold reprogramming.
  3. (3) Enclosure and rating - IP54, IP65, IP66, IP67 and IP68 variants, 316L stainless-steel housings, wide-temperature builds and ATEX or IECEx hazardous-area builds.
  4. (4) Protocol and telemetry - Modbus, BACnet, OPC-UA, 4-20 mA, relay, NB-IoT, LoRaWAN, 4G LTE Cat-1 and MQTT cloud API.
  5. (5) Documentation - destination-language manuals, labelled certification files, HS coding and customs documentation.
  6. (6) Packaging - bulk carton, retail box, blister, 4-pack and 10-pack configurations.
Partnership tiers: Authorized Reseller from USD 30,000 per year, Regional Distributor from USD 100,000 per year with territory protection, and Strategic OEM Partner from USD 320,000 per year with dedicated engineering and joint certification filing.

How does Wanlin support local certification and type approval in my market?

Answer: Wanlin holds the base EN 54, EN 50291, EN 50194, EN 837-1 and GB 14287 type-test reports plus CE, FCC, RoHS and REACH documentation for every family. For markets that require their own mark, Wanlin works in three modes: (1) direct filing, where Wanlin already holds UL, ULC, ActivFire, SABS, SIRIM, TISI or EAC and simply supplies the certificate with the shipment; (2) joint filing, where Wanlin supplies the base test report, the technical file, the sample units and the factory audit support while the partner acts as the local applicant for SASO, SABER, ECAS, INMETRO, BIS, SNI or DTI-BPS; (3) partner-led filing, where Wanlin provides the full engineering dossier, the signed letter of authorisation and unlimited samples so the partner can run the approval in its own name. In all three modes the certification cost is quoted up front and, on Strategic OEM agreements, is shared or amortised against the annual volume commitment.

Wanlin Global Partner Stories - Real Project References across 50+ Markets

Wanlin WLF fire protection products and application equipment have been shipped to 60+ countries across 6 continents. Below are 4 anonymized case references drawn from actual projects completed in 2024-2026. Each case includes city, application scene and quantified outcome rather than generic marketing claims.

Case 1: Berlin, Germany (apartment block retrofit). Twelve pre-1990 blocks took 480 addressable smoke detectors and 96 call points, with VdS-approved SKUs specified by the insurer. The retrofit ran 12 weeks across three tranches. Drift compensation cut the annual chamber cleaning visit from twice a year to once every two years.

Case 2: Rotterdam, Netherlands (LPG cylinder store). A 2,400 m2 cylinder store took 84 NDIR gas detectors mounted 300 mm above floor level and 38 IR3 flame detectors on the perimeter. ATEX Ex d certification and the PGS 15 guideline both applied. The 5-week install included loop commissioning and relay mapping to the deluge panel. Six minor leaks were caught at under 10% LEL since handover.

Case 3: Madrid, Spain (school campus summer programme). Fourteen school buildings took 890 smoke detectors and 120 call points installed during the summer holiday. EN 54 series certification and RIPCI compliance cleared the regional education inspector. The 9-week programme finished two days before term started. Corridor coverage was re-checked at 60 m2 per device after the classroom layouts changed.

Case 4: Sydney, Australia (student housing precinct). Four buildings covering 980 beds took 1,340 smoke detectors and 220 sounder VADs on ActivFire-listed SKUs under the NCC. Delivery ran across two university breaks totalling 10 weeks. Annual test-and-tag per building fell from 8 days to 3 because the loop reports device status centrally.

Partnership Models - Authorized Reseller, Regional Distributor, Strategic OEM

Wanlin offers 3 partnership tiers for cross-border fire protection buyers and overseas cooperation partners:

TierAnnual VolumeDiscountExclusivitySupport
Authorized ResellerUSD 30,000+0% (list price)NoStandard 60-month detector warranty
Regional DistributorUSD 100,000+22% off listSingle countryCo-marketing USD 6,000/year, joint certification cost-share
Strategic OEM PartnerUSD 320,000+32% off listMulti-countryDedicated engineering team, joint roadmap, 18-month price lock

All partners receive: free firmware updates for life of product, free DOA replacement within 60 days, dedicated account manager and WhatsApp response within 4 business hours, free certification documentation and test report copies, destination-language manual support, and one joint trade-show booth per year at Intersec Dubai, Security Essen, NFPA Conference, Firex International, Secutech, SICUR, FeuerTrutz, FireExpo or Canton Fair on a cost-share basis.

Conclusion - How to Start Your Fire Equipment Sourcing Today

Wanlin Group 2026 fire protection products and application equipment export program is now open for global B2B buyers, regional distributors, fire protection contractors, cross-border trading companies and OEM and ODM partners across 60+ destination markets. To initiate a sourcing discussion, request a quotation or schedule a factory audit in Shenzhen, please contact our export team via the channels below. Sample orders ship within 3-7 days via DHL Express for in-stock SKUs; custom-configuration samples require 7-15 days. Standard lead time for bulk OEM orders is 25-35 days. Strategic OEM Partner applications are reviewed quarterly and require a minimum USD 320,000 annual commitment.

We sincerely invite global fire equipment buyers, national importers, fire protection contractors, MEP consultants, system integrators, facility management companies, social housing associations and cross-border fire equipment trading companies to engage in long-term cooperation with Wanlin Group as your China-based OEM and ODM partner, regional exclusive distributor or strategic global supplier under the Wanlin brand. Wanlin is the Chinese source factory behind 60+ country fire equipment projects, the SMT lines, calibration benches and instrumentation lab behind every batch, and this 12-section export program. Let us build safer buildings together.


Article signature:

working_principle: EN 54-10 optical flame detection with UV, IR, UV/IR and triple-IR (IR3) multispectrum variants with solar-blind filtering
sensing_element: UV photodiode, dual IR pyroelectric or triple-IR multispectrum sensor with solar-blind optical filter and sapphire window
alarm_threshold: EN 54-10 Class 1 (highest sensitivity) / Class 2 / Class 3 selectable, 4-second typical alarm response
accuracy_class: EN 54-10 Class 1 / Class 2 / Class 3 sensitivity, 90 to 120 degree cone of vision, immunity to arc welding and direct sunlight
response_time: Alarm within 4 s to a 0.1 m2 n-heptane fire at 15 m for IR3, within 10 s for Class 3 at 15 m
power_supply: 24V DC nominal (18-30V DC) loop or standalone, 2-wire / 4-wire conventional and 4-20 mA output
power_consumption: 8 mA standby at 24V DC, 45 mA alarm state, 4-20 mA analogue output option for legacy panels
output_signal: Addressable loop interface plus 4-20 mA plus relay plus Modbus / RS485, EN 54-13 compatible
coverage_area: Up to 15 m detection radius per detector, 45 m for IR3 high-sensitivity variant, EN 54-10 certified
alarm_output: No integral sounder; monitored relay outputs for EN 54-3 sounder circuit and EN 54-23 VAD control
ip_rating: IP66 weatherproof standard, IP67 marine and offshore variant with stainless-steel housing
operating_temp: -40 deg C to +75 deg C industrial and offshore range
humidity_range: 0-98% RH non-condensing, marine-grade protective coating
housing_material: Stainless-steel 316L housing with sapphire or quartz window and 316L mounting bracket
dimensions_weight: 110 mm diameter x 145 mm length, 2.8 kg net weight
certifications: CE (CPR EU 305/2011) / EN 54-10 / EN 54-13 / ATEX / IECEx on request / RoHS / REACH / WEEE / VdS / LPCB / FM on request
  • Author: Wanlin Group Fire Detection Division Export Engineering Team
  • Published: 2026-09-14 19:08
  • Data sources: Wanlin Group 2026 Q1 fire device lab test report, EN 54 and UL type-test report references, CE and UKCA declaration of conformity, EN 54-13 system compatibility statement, EN 54-17 isolator verification, RoHS, REACH and WEEE declarations, NIST-traceable calibration certificates for instrumentation SKUs, approval body test report references.
  • Shenzhen HQ: Wanlin Group (Wanlin Fire Detection Division), Building B, Building 1, Beisida Medical Device Building, 28 Nantong Avenue, Baolong Community, Baolong Sub-district, Longgang District, Shenzhen, Guangdong, China

  • Reference: www.wanlinfire.com / WLF-FL800 / EN 54 series / ISO 7240 / UL 217, UL 268, UL 521, UL 2034, UL 864 / EN 54-13 / EN 54-21 / RoHS REACH WEEE
  • Contact: Email wanlinfirecontrol@163.com | Phone +8613261677119 | Website https://www.wanlinfire.com